Price: AED 15,900
DA2808
More product information
Ceiling extractor with energy-efficient LED lighting and light-touch switches for easy use.
- Elegant design - harmonious in the kitchen environment
- Unique user convenience – Con@ctivity
Con@ctivity
Innovative convenience: the cooker hood reacts automatically to settings on the hob. - Powerful – 725 m3/h in Booster level
- Energy-efficient and quiet - powerful ECO motor
ECO motor
The ECO motor operates with DC current and saves up 70% energy compared to conventional motors. Thanks to this technology, it operates very quietly yet as powerfully as all fans used by Miele. - Efficient filtration- 10-ply stainless-steel grease filter
Stainless steel grease filters (10-layer)
Looks great and does a good job: effective grease filtering and easy cleaning in a dishwasher.
Product details - DA 2808
Construction type | |
---|---|
Ceiling extractor | • |
Operating modes | |
Type of air guide | Can be retrofitted |
Recirculation conversion kit (order separately) | DUU 2900 |
Active charcoal filter (order separately) | DKF 20-P |
Design | |
Colour | Stainless steel |
Edge extraction | • |
User convenience | |
Miele@home | • |
Automatic function Con@ctivity | • |
Electronic controls | • |
Controls | Light-touch switches with LEDs |
Miele@mobile app | • |
Power levels (number without Booster level) | 3 |
Booster levels | 1 |
Programmable Booster level switch-off | • |
Run-on time 5/15 min. | • Run-on functionOdour-free room air: after cooking, the fan can be set to switch off automatically after a 5 or 15 minute run-on period. |
Grease filter saturation indicator | • |
Grease filter saturation indicator | • |
Active charcoal filter saturation indicator | • |
Efficiency and sustainability | |
Energy efficiency class (A+++ to D) | A+ |
Annual energy consumption in kWh/year | 27.6 27.6 27.6 |
Fluid dynamic efficiency class | A A |
Lighting efficiency class | A A |
Grease filtering efficiency class | B B |
PowerManagement system | • Power management systemThe intelligent Power management system automatically conserves energy when the cooker hood is in use without the user having to intervene. Within a predetermined time frame, power is automatically switched down to the next lowest setting. And a lower fan setting means automatically less energy consumption. |
Cleaning and care | |
Easy-to-clean canopy interior – CleanCover | • • |
Filter system | |
Number of dishwasher-safe stainless steel grease filters (10-ply) | 2 |
Lighting | |
LED | • |
Number x W | 4 x 3 W |
Light intensity in Lx | 720 lx |
Colour temperature in K | 3500 Kelvin |
Dimmer function | • |
Fan | |
Dual-action blower | • |
DC motor | • |
Exhaust air | |
Air throughput in Level 1 (m³/h) according to EN 61591 | 200 |
Air throughput in Level 2 (m³/h) according to EN 61591 | 310 |
Air throughput in Level 3 (m³/h) according to EN 61591 | 450 |
Air throughput in booster level 1 (m³/h) | 725 |
Sound power in Level 1 (dB(A) re 1 pW) according to EN 60704-3 | 35 |
Sound power in Level 2 (dB(A) re 1 pW) according to EN 60704-3 | 44 |
Sound power in Level 3 (dB(A) re 1 pW) according to EN 60704-3 | 53 |
Sound power in Booster level 1 (dB(A) re 1 pW) acc. to EN 60704-3 | 65 |
Sound pressure in Level 1 (dB(A) re 20 µPa) according to EN 60704-2-13 | 20 |
Sound pressure in Level 2 (dB(A) re 20 µPa) according to EN 60704-2-13 | 30 |
Sound pressure in Level 3 (dB(A) re 20 µPa) according to EN 60704-2-13 | 38 |
Sound pressure in Booster level 1 (dB(A) re 20 µPa) acc. to EN 60704-2-13 | 50 |
Recirculation | |
Air throughput in Level 1 (m³/h) according to EN 61591 | 115 |
Air throughput in Level 2 (m³/h) according to EN 61591 | 215 |
Air throughput in Level 3 (m³/h) according to EN 61591 | 335 |
Air throughput in Booster level 1 (m³/h) according to EN 61591 | 535 |
Sound power in Level 1 (dB(A) re 1 pW) according to EN 60704-3 | 43 |
Sound power in Level 2 (dB(A) re 1 pW) according to EN 60704-3 | 53 |
Sound power in Level 3 (dB(A) re 1 pW) according to EN 60704-3 | 62 |
Sound power in Booster level 1 (dB(A) re 1 pW) acc. to EN 60704-3 | 72 |
Sound pressure in Level 1 (dB(A) re 20 µPa) according to EN 60704-2-13 | 28 |
Sound pressure in Level 2 (dB(A) re 20 µPa) according to EN 60704-2-13 | 39 |
Sound pressure in Level 3 (dB(A) re 20 µPa) according to EN 60704-2-13 | 47 |
Sound pressure in Booster level 1 (dB(A) re 20 µPa) acc. to EN 60704-2-13 | 57 |
Safety | |
Safety shut-off | • |
Technical data | |
Overall hood height for extraction mode and external in mm | 339 |
Overall hood height for recirculation and external in mm | 339 |
Overall height for vented and external in in. (mm) | 339 |
Overall height for extraction mode and external mode cooker hoods in mm | 339 |
Overall height for recirculation in in. (mm) | 339 |
Overall height for recirculation mode cooker hoods in mm | 339 |
Canopy width in in. (mm) | 880 |
Canopy height in in. (mm) | 342 |
Depth of hood canopy in in. (mm) | 500 |
Minimum height above electric hobs in mm | 450 |
Minimum safety distance above gas hobs (max. 12.6 kW total power, burner ≤ 4.5 kW) in mm | 650 |
Net weight in kg | 17 |
Length of supply lead in m | 1.5 |
Standard plug fitted | • |
Total rated load in kW | 0.117 |
Voltage in V | 230 |
Fuse rating in A | 10 |
Frequency in Hz | 50 |
Number of phases | 1 |
Installation notes | |
Extraction ducting connection at top | • |
Extraction ducting connection on side | • |
Extraction ducting connection at top, rear, and si | • |
Diameter of extraction ducting connection in mm | 150 |
Accessories included | |
Non-return flap | • |
AED 15,900
Subject to technical changes; no liability accepted for the accuracy of the information given!